APC test PB0-200 exam dumps Exam PB0-200 APC NCPI Design PB0-200 Testing Engine - Test4pass

PB0-200 Exam

APC NCPI Design

  • Exam Number/Code : PB0-200
  • Exam Name : APC NCPI Design
  • Questions and Answers : 115 Q&As
  • Update Time: 2011-09-21
  • Price: $ 119.00 $ 69.00

Free PB0-200 Demo Download

Test4pass offers free demo for APC PB0-200 exam (APC NCPI Design). You can check out the interface, question quality and usability of our practice exams before you decide to buy it. We are the only one site can offer demo for almost all products.


 

Exam Description

It is well known that PB0-200 exam test is the hot exam of APC certification. Test4pass offer you all the Q&A of the PB0-200 real test . It is the examination of the perfect combination and it will help you pass PB0-200 exam at the first time!

Why choose Test4pass PB0-200 braindumps

Quality and Value for the PB0-200 Exam
100% Guarantee to Pass Your PB0-200 Exam
Downloadable, Interactive PB0-200 Testing engines
Verified Answers Researched by Industry Experts
Drag and Drop questions as experienced in the Actual Exams
Practice Test Questions accompanied by exhibits
Our Practice Test Questions are backed by our 100% MONEY BACK GUARANTEE.

APC APC PB0-200 exam braindumps questions and answers

¡¡
¡¡
Exam : APC PB0-200
Title : APC NCPI Design


1. What are two reasons why a fully rated UPS (output kW = output kVA) is more compatible with today's IT loads than an 80%-rated UPS (output kW = output kVA at a 0.8 power factor)? (Choose two.)
A. 80%-rated UPSs are more efficient.
B. Today's IT loads are power-factor corrected.
C. Fully-rated UPSs have superior output voltage control.
D. Fully-rated UPSs make it less likely to undersize the UPS.
E. Today's IT loads lock up when powered by an 80%-rated UPS.
Answer: BD

2. How do you achieve full system redundancy in a precision air conditioning system?
A. install multiple air conditioning systems in an N+1 configuration
B. install a properly-sized DX air cooled unit with chilled water back-up
C. install a properly-sized air conditioning unit with redundant compressors
D. install Building System cooling (comfort cooling) with an air conditioning unit in standby
Answer: A

3. A company has an existing data center where the temperature does not go below 27?Celsius (80?Fahrenheit). There are hot spots in the data center where the temperature is even higher. There is one 40kW chilled-water unit and 60kW of IT heat load in the space. The customer wants to reduce the temperature to 22?Celsius (72?Fahrenheit) and provide N+1 redundancy. What is the most reliable and cost-effective solution?
A. add one 40kW chilled-water unit
B. add two 60kW chilled-water units
C. add two 40kW chilled-water units
D. add one 40kW refrigerant-based unit
E. add one 60kW refrigerant-based unit
Answer: C

4. What is the most accurate way to determine the capacity of an existing standby generator?
A. ask the facility manager
B. calculate 30% over the UPS capacity
C. look at the generator name plate in the genset room
D. calculate capacity based on the load the generator is powering
Answer: C

5. A site requires redundant power feeds to single-corded servers. What is a possible redundant configuration?
A. two single-module UPSs feeding one rack-mount Automatic Transfer Switch and one outlet strip per rack
B. two single-module UPSs each feeding dual-panel distribution boards, which in turn feed two outlet strips per rack
C. two single-module UPSs each feeding two outlet strips per rack; plugging half the servers in one strip and the other half in another strip
D. two single-module UPSs each fed from separately derived utility sources; sources that come from one of two independent utility substations
Answer: A

6. An IT manager wants one hour of UPS runtime on a Voice over IP (VoIP) solution that will be located in a small wiring closet. To get the full hour of runtime and continuous operation, what else must be in place?
A. The closet must have sufficient cooling for that period.
B. Shutdown software should be loaded on the VoIP server.
C. The UPS must be oversized in wattage to provide this runtime.
D. The equipment must be installed in a full enclosure for proper security.
Answer: A

7. Which two products are appropriate for an IT network wiring closet? (Choose two.)
A. single-phase UPS
B. 800 amp DC rectifier
C. 4-post open frame rack
D. 10kVA three-phase UPS
E. 15-ton computer room air conditioner
Answer: AC

8. A company has a 30kW N+1 InfraStruXure solution in their small data center. In the event of a power module failure, it wants e-mail notification that there is a loss of redundancy. The only connection is a LAN connection for monitoring. What should you do?
A. using the InfraStruXure Manager, connect into the RJ45 port and configure the e-mail notification feature
B. using an Out of Band Management Card, connect into an external modem and configure the e-mail notification feature
C. using the serial port on the UPS, connect the UPS solution to a desktop computer and configure the e-mail notification feature
D. using the Building Management Card, connect the UPS solution to the facility Building Management software and configure the e-mail
notification feature
Answer: A

9. A remote office for a small business has 20 employees. Its IT equipment supports four file servers, e-mail, storage, and Internet access. Which three products are appropriate for this office's IT room that has no IT staff? (Choose three.)
A. 30kW N+1 UPS
B. 12kVA N+1 UPS
C. 4-post rack
D. 15-ton computer room air conditioner
E. remote security and environmental monitoring
Answer: BCE

10. You have specified that a 1000 VA rack-mount UPS solution be added to your client's existing data center. Considering the size of the UPS, which service product is appropriate?
A. Load Bank
B. Thermography
C. Extended Warranty
D. Preventive Maintenance
Answer: C

11. What is a common application for 2-post racks?
A. telecom
B. server room
C. remote office
D. IT data center
Answer: A

12. If a company requests that its UPS output power be distributed to the racks through an isolation transformer, what are they trying to do?
A. decrease the cable size to the load
B. increase the efficiency of the system
C. increase availability throughout the data center
D. prevent electrical noise from locking up the servers
Answer: D

13. Click the Calculator button. A medium-size data center has been retrofitted and the new IT equipment requires 39kW at a power factor 0.90. The existing UPS system is 40kVA. Which two actions should you take? (Choose two.)
A. keep the actual UPS system: 40kVA means 40kW
B. replace the diesel generator to cover the extra load
C. replace the actual UPS system with a minimum 45kVA
D. check the entire UPS installation to make sure it is able to support the new load
Answer: CD

14. A data center with raised-floor air distribution has hot spot problems in the equipment racks closest to the air conditioners. What are two possible solutions to this problem? (Choose two.)
A. moving the racks closer to the air conditioners
B. increasing airflow rate from the air conditioners
C. moving the racks away from the air conditioners
D. decreasing airflow rate from the air conditioners
Answer: CD


Click Online chat to talk with us , get more informations about APC APC PB0-200 practice exam study guides questions and answers

Test4pass PB0-200 Exam Features

Quality and Value for the PB0-200 Exam

Test4pass Practice Exams for APC PB0-200 are written to the highest standards of technical accuracy, using only certified subject matter experts and published authors for development.

100% Guarantee to Pass Your PB0-200 Exam

If you prepare for the exam using our Test4pass testing engine, we guarantee your success in the first attempt. If you do not pass the APC PB0-200 exam (ProCurve Secure WAN) on your first attempt we will give you a FULL REFUND of your purchasing fee AND send you another same value product for free.

APC PB0-200 Downloadable, Printable Exams (in PDF format)

Our Exam PB0-200 Preparation Material provides you everything you will need to take your PB0-200 Exam. The PB0-200 Exam details are researched and produced by Professional Certification Experts who are constantly using industry experience to produce precise, and logical. You may get questions from different web sites or books, but logic is the key. Our Product will help you not only pass in the first try, but also save your valuable time.

PB0-200 Downloadable, Interactive Testing engines

We are all well aware that a major problem in the IT industry is that there is a lack of quality study materials. Our Exam Preparation Material provides you everything you will need to take a certification examination. Like actual certification exams, our Practice Tests are in multiple-choice (MCQs) Our APC PB0-200 Exam will provide you with free PB0-200 dumps questions with verified answers that reflect the actual exam. These questions and answers provide you with the experience of taking the actual test. High quality and Value for the PB0-200 Exam:100% Guarantee to Pass Your APC exam and get your APC Certification.

Test4pass PB0-200 exam
Test4pass PB0-200 pdf exam
Test4pass PB0-200 braindumps
Test4pass PB0-200 study guides
Test4pass PB0-200 trainning materials
Test4pass PB0-200 simulations
Test4pass PB0-200 testing engine
Test4pass PB0-200 vce
Test4pass PB0-200 torrent
Test4pass PB0-200 dumps
free download PB0-200
Test4pass PB0-200 practice exam
Test4pass PB0-200 preparation files
Test4pass PB0-200 questions
Test4pass PB0-200 answers

http://www.test4pass.com/PB0-200-exam.html The safer.easier way to get APC Certification .

Other APC Exams


Guarantee | Buying Process | F.A.Q. | Payment | Refundment Term | Semples | Testing Engine | privacy | Contact | Sitemap 1 2 3 4

Copyright©2006-2009 sale test4pass Limited. All Rights Reserved

sale test4pass materials do not contain actual questions and answers from Microsoft's Cisco's Certification Exams.