HP0-390 Exam
Planning & Deployment of HP BladeSystem Solutions
- Exam Number/Code : HP0-390
- Exam Name : Planning & Deployment of HP BladeSystem Solutions
- Questions and Answers : 120 Q&As
- Update Time: 2011-09-21
- Price:
$ 119.00$ 69.00
Free HP0-390 Demo Download
Test4pass offers free demo for Certification III HP0-390 exam (Planning & Deployment of HP BladeSystem Solutions). You can check out the interface, question quality and usability of our practice exams before you decide to buy it. We are the only one site can offer demo for almost all products.
Exam Description
It is well known that HP0-390 exam test is the hot exam of HP certification. Test4pass offer you all the Q&A of the HP0-390 real test . It is the examination of the perfect combination and it will help you pass HP0-390 exam at the first time!
Why choose Test4pass HP0-390 braindumps
Quality and Value for the HP0-390 Exam
100% Guarantee to Pass Your HP0-390 Exam
Downloadable, Interactive HP0-390 Testing engines
Verified Answers Researched by Industry Experts
Drag and Drop questions as experienced in the Actual Exams
Practice Test Questions accompanied by exhibits
Our Practice Test Questions are backed by our 100% MONEY BACK GUARANTEE.
HP Certification III HP0-390 exam braindumps questions and answers
¡¡
Exam : HP HP0-390
Title : Planning & Deployment of HP BladeSystem Soluti
1. When is it required to use a load-balancing signal cable?
A. When using facility DC power.
B. When using three-phase A/C power.
C. When two power enclosures are connected to a scalable bus bar.
D. When two power enclosures are connected to server blade enclosures using power bus boxes.
Answer: C
2. What is the maximum HP BladeSystem configuration using a 42U rack and redundant power?
A. two power enclosures, six server blade enclosures
B. four power enclosures, four server blade enclosures
C. four power enclosures, five server blade enclosures
D. six power enclosures, six server blade enclosures
Answer: C
3. Which file customizes the scripted Microsoft Windows 2003 installation using RDP 1.60?
A. wnet.txt
B. w2k3.txt
C. unattend.txt
D. win2003.txt
Answer: A
4. Which hardware components are required to provide redundant SAN connectivity for an enhanced server blade enclosure fully populated with ProLiant BL20p G3 server blades? Select FOUR.
A. two GbE2 Interconnect Switches
B. one Fibre Channel mezzanine host bus adapter for each server blade
C. two Fibre Channel mezzanine host bus adapters for each server blade
D. one Fibre Channel balcony host bus adapter for each server blade
E. two Fibre Channel balcony host bus adapters for each server blade
F. two Octal FC interconnect modules
G. two Fibre Channel Retimer mezzanine cards
H. two 64-bit PCI-X expansion slot host bus adapters for each server blade
Answer: ABFG
5. Which software packages make up the HP ProLiant Essentials Rapid Deployment Pack? Select THREE.
A. Altiris Deployment Server
B. Automation Manager
C. HP BladeSystem Integrated Management
D. Integrated Lights-Out Advanced
E. ProLiant Integration Module
F. SmartStart Scripting Toolkit
Answer: AEF
6. You need to enable maximum trunk bandwidth between both GbE2 interconnect switches and an external production network infrastructure. How many RJ-45 network cables are necessary for an enhanced server blade enclosure that is fully populated with ProLiant BL30p server blades?
A. 6
B. 8
C. 12
D. 18
Answer: C
7. You are deploying Red Hat Enterprise Linux AS 3 to ProLiant BL30p server blades using RDP 1.60 WE. These server blades are connected to the MSA1000 storage solution from which they must boot the operating system. You located and modified the bl30p.ks.cfg kickstart file. During the Linux deployment, the Linux installer reports that it cannot read the contents of the kickstart file. Why?
A. RDP 1.60 WE does not support deploying Red Hat Enterprise Linux AS 3 to ProLiant BL30p server blades
B. you did not enable Linux support in the Selective Storage Presentation (SSP) of the MSA1000
C. you used a Windows-based editor such as Notepad which inserted unsupported CR+LF in the kickstart file
D. you did not modify the RDP job for the appropriate NFS server
Answer: C
8. Which HP server blade supports two non-hot-pluggable 2.5-inch ATA drives?
A. ProLiant BL20p G2
B. ProLiant BL20p G3
C. ProLiant BL30p
D. ProLiant BL40p
Answer: C
9. Which utility enables you to approximate the power and heat load per rack, and calculate the full environmental impact of racks with varying configurations and loads?
A. Enterprise Configurator
B. ProLiant BL p-Class Power Calculator
C. Rack and Power Calculator
D. Site Installation Preparation Utility
Answer: D
10. Which components must be installed in the HP BladeSystem to enable SAN connectivity for the ProLiant BL20 and BL30 series server blades? Select THREE.
A. pass-through mezzanine board for the interconnect switch
B. GbE2 Interconnect Switches
C. SAN-enabled server blade enclosure management module
D. mezzanine or balcony server blade host bus adapters
E. eight-port interconnect module for the interconnect switch
F. server blade enclosure with enhanced backplanes
Answer: ADE
11. Which hardware information file must you use in the RDP 1.60 deployment job to have ProLiant BL20p G2/G3 server blades boot Red Hat Enterprise Linux AS 3 from SAN?
A. bl20p-a.ini
B. bl20p-h.ini
C. linux-h.ini
D. pl-bfs.ini
Answer: D
12. You install and configure the Altiris Deployment Solution from the HP RDP 60 CD on a supported ProLiant server running Microsoft Windows Server 2003. Then you install the ProLiant Integration Module. When you open the Deployment Server Console, you find the SmartStart Toolkit and OS Imaging Events and the SmartStart Toolkit Hardware Configuration Events folders, but no scripted install jobs for any of the ProLiant BL server blades. Why?
A. no RDP licenses were available, and only the free portion of the ProLiant Integration Module installed
B. the Deployment Server Agent was not installed and configured
C. the RDP pre-deployment environment was not configured correctly
D. the Windows and Linux scripted install jobs were not selected by default when installing the ProLiant Integration Module
Answer: D
13. You configured RDP with the Rip-and-Replace functionality and chose to re-deploy the computer automatically when a new server blade was detected in the appropriate server bay. The failed server blade was configured to boot from internal drives, but was also connected to an MSA1000 that is shared among several server blades within the same server blade enclosure. After RDP replays the appropriate jobs on the new server blade, you can no longer access the MSA1000. Why?
A. The dual-path software was not reconfigured with the new server blade serial number.
B. The MSA1000 access license was not migrated from the failed server blade to the new server blade.
C. The new server blade host bus adapters (HBAs) were not enabled in the QLogic Fast!UTIL utility.
D. The Selective Storage Presentation (SSP) was not reconfigured for the new server blade HBA world wide IDs.
Answer: D
14. Where do the operating system distribution files reside during a Red Hat Enterprise Linux AS 3 deployment using RDP 1.60?
A. on a Linux Network File System (NFS) server
B. on the deployment server in the CD-ROM drive
C. on the deployment server in the Client Access Point share
D. on the deployment server in the RDP eXpress database
Answer: A
Click Online chat to talk with us , get more informations about HP Certification III HP0-390 practice exam study guides questions and answers
Test4pass HP0-390 Exam Features
Quality and Value for the HP0-390 Exam
Test4pass Practice Exams for HP HP0-390 are written to the highest standards of technical accuracy, using only certified subject matter experts and published authors for development.
100% Guarantee to Pass Your HP0-390 Exam
If you prepare for the exam using our Test4pass testing engine, we guarantee your success in the first attempt. If you do not pass the Certification III HP0-390 exam (ProCurve Secure WAN) on your first attempt we will give you a FULL REFUND of your purchasing fee AND send you another same value product for free.
HP HP0-390 Downloadable, Printable Exams (in PDF format)
Our Exam HP0-390 Preparation Material provides you everything you will need to take your HP0-390 Exam. The HP0-390 Exam details are researched and produced by Professional Certification Experts who are constantly using industry experience to produce precise, and logical. You may get questions from different web sites or books, but logic is the key. Our Product will help you not only pass in the first try, but also save your valuable time.
HP0-390 Downloadable, Interactive Testing engines
We are all well aware that a major problem in the IT industry is that there is a lack of quality study materials. Our Exam Preparation Material provides you everything you will need to take a certification examination. Like actual certification exams, our Practice Tests are in multiple-choice (MCQs) Our HP HP0-390 Exam will provide you with free HP0-390 dumps questions with verified answers that reflect the actual exam. These questions and answers provide you with the experience of taking the actual test. High quality and Value for the HP0-390 Exam:100% Guarantee to Pass Your Certification III exam and get your Certification III Certification.
Test4pass HP0-390 examTest4pass HP0-390 pdf exam
Test4pass HP0-390 braindumps
Test4pass HP0-390 study guides
Test4pass HP0-390 trainning materials
Test4pass HP0-390 simulations
Test4pass HP0-390 testing engine
Test4pass HP0-390 vce
Test4pass HP0-390 torrent
Test4pass HP0-390 dumps
free download HP0-390
Test4pass HP0-390 practice exam
Test4pass HP0-390 preparation files
Test4pass HP0-390 questions
Test4pass HP0-390 answers
http://www.test4pass.com/HP0-390-exam.html The safer.easier way to get Certification III Certification
.




